Customized: | Customized |
---|---|
Certification: | CE, FDA, ISO13485 |
Scale: | Large |
Still deciding? Get samples of US$ 1000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High Flow Nasal Cannula Oxygen Therapy System HFNC CPAP Manufacturing
The HFNC system offers high flow oxygen therapy to patients.
It is a new method of respiratory therapy compared with traditional way of using ventilators.
Medical device treatment: In addition to drug treatment, respiratory support treatments relying on medical devices, such as oxygen therapy, invasive mechanical ventilation, extracorporeal membrane oxygenation (ECMO), and circulatory support are of much helpful to those the most serious cases of coronavirus pneumonia. It also plays an important role in the treatment of critically ill patients. As there is no enough ventilators, it is time to introduce our high flow oxygen blender for replacement, it is very helpful for the early infection cases and the recovery patients from critical stages.
Model | LM-2000B | |||
Classification | Class IIb ,Type B,IPX1 | |||
Supply Voltage/Frequency | 220V/ 110V 50/60Hz | |||
Heater Plate | 150W | |||
Heater Wire(Max.) | 22V-,2.73A, 60W, 50/60Hz | |||
Heater Plate Over-temperature Cut Off | 95±5ºC | |||
Temperature monitoring | 0-75ºC | |||
Temperature control settings |
Heated wire mode(mode indicator lighted) | |||
Temperature grade (with indicator status) | Continuous flow range | Delivered patient temperature | ||
P1 (o○○) | 5L/min-60L/min | 25-29ºC | ||
P2 (oo○) | 5L/min-60L/min | 29-35ºC | ||
P3 (ooo) | 5L/min-60L/min | 35-39ºC | ||
Non-heated wire mode(mode indicator non-lighted) | ||||
Temperature grade (with indicator status) | Continuous flow range | Delivered patient temperature | ||
P1 (o○○) | 5L/min-60L/min | P1:23-27ºC | ||
P2 (oo○) | 5L/min-60L/min | P2:27-32ºC | ||
P3 (ooo) | 5L/min-60L/min | P3:32-37ºC |
Model | LM-2000B |
Humidity Performance | >12mg/L@5-60Lpm |
Display | Three digit,0.56 inch,7 segment LED 10-70ºC,Accuracy:±2ºC( In 25-45ºC temperature range) |
Dimension | 135mm(W)*145mm(H)*155mm(D) (without chamber) |
Weight | 2.5kg(max) (without chamber) 3.2 kg(max) (with chamber filled water) |
Operating environment | Temperature:18ºC-26ºC Relative humidity : ≤95%(without condensation) Atmospheric pressure: 86KPa-106Kpa |
Transportation and Storage environment | Temperature: -40ºC~55ºC Relative humidity : ≤95%(without condensation) |
Electrical safety standard | IEC60601-1/GB9706.1-2007 |
EMC safety standard | IEC/EN 60601-1-2/YY0505-2012 |
Device specific standard | ISO8185:2007/YY0786-2010 |