Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

Product Details
Disposable: Non-Disposable
Certification: CE, ISO
Power Source: Manual
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
  • Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
  • Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
  • Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
  • Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
  • Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
Find Similar Products
  • Overview
  • Product Description
  • Packaging & Shipping
  • FAQ
  • Exhibitions
Overview

Basic Info.

Model NO.
NOVA-0314
Material
Rubber / Plastic
Samples
Free Samples
Function
Transfer Pipette
Transport Package
Standard Export Carton
Specification
0.1-2.5μl,0.5-10μl 5-50μl 2-20μl etc
Trademark
OEM/Novaluck
Origin
China
HS Code
8413190000
Production Capacity
200000 CTN/Day

Product Description

Product Description

Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

Key Features
•   Fully autoclavable
•   Ergonomic design provides excellent operating  experience
•   Easy-to-read volume display
•   The pipettes cover the volume range from 0.1μL to 5mL
•   Easy calibration and maintenance
•   Manufactured from innovative materials
•   Each MicroPette Plus supplied with an
•   individual calibration certificate according to ISO8655

Single-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Accuracy error  Precision error
      % μl % μl
0.1-2.5μl 0.05μl 2.5 2.50% 0.0625 2.00% 0.05
1.25 3.00% 0.0375 3.00% 0.0375
0.25 12.00% 0.03 6.00% 0.015
0.5-10μl 0.1μl 10 1.00% 0.1 0.80% 0.08
5 1.50% 0.075 1.50% 0.075
1 2.50% 0.025 1.50% 0.015
2-20μl 0.5μl 20 0.90% 0.18 0.40% 0.08
10 1.20% 0.12 1.00% 0.1
2 3.00% 0.06 2.00% 0.04
5-50μl 0.5μl 50 0.60% 0.3 0.30% 0.15
25 0.90% 0.225 0.60% 0.15
5 2.00% 0.1 2.00% 0.1
10-100μl 1μl 100 0.80% 0.8 0.15% 0.15
50 1.00% 0.5 0.40% 0.2
10 3.00% 0.3 1.50% 0.15
20-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
20 3.00% 0.6 1.00% 0.2
50-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
50 1.00% 0.5 0.40% 0.2
100-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
100 2.00% 2 0.70% 0.7
200-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
200 0.90% 1.8 0.30% 0.6
1000-5000μl 50μl 5000 0.50% 25 0.15% 7.5
2500 0.60% 15 0.30% 7.5
1000 0.70% 7 0.30% 3
 
Fixed Volume Pipettes
Volume Range Increment Test Volume Accuracy error  Precision error
      % μl % μl
5μl - 5μl 1.3% 0.065 1.2% 0.06
10μl - 10μl 0.8% 0.08 0.8% 0.08
20μl - 20μl 0.6% 0.12 0.5% 0.1
25μl - 25μl 0.5% 0.125 0.3% 0.075
50μl - 50μl 0.5% 0.25 0.3% 0.15
100μl - 100μl 0.5% 0.5 0.3% 0.3
200μl - 200μl 0.4% 0.8 0.2% 0.4
250μl -- 250μl 0.4% 1.0 0.2% 0.5
500μl - 500μl 0.3% 1.5 0.2% 1.0
1000μl - 1000μl 0.3% 3.0 0.2% 2.0
2000μl - 2000μl 0.3% 6.0 0.15% 3.0
5000μl - 5000μl 0.3% 15 0.15% 7.5

 

Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

 

Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab UseMechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

 

  
Packaging & Shipping
Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use
Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

 

FAQ
Q1. Is free sample available? 
A: Yes, sure. we are happy to send free samples of some items for quality evaluation first. Please feel free to contact us.
Q2. What is your lead time? 
A: Normally 3-7 days in general
Q3. How does your factory do regarding quality control? 
A: Quality is priority. All raw material we used are non-toxic, environmental-friendly. We have a professional QA/QC team to ensure the quality. And all pass the test report.
Q4. Do you accept OEM or ODM order? 
A: Yes, sure. we accept both OEM and ODM for customers. 
Q5. What are your terms of delivery?
A: We can accept EXW, FOB, CIF, etc. depends on which one you prefer.
Q6. What is the payment way? 
A: TT, westeruion, ect.
Exhibitions

Mechanical Autoclavable Single Channel Adjustable Variable Volume Pipette Lab Use

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier